Infusion Pump
Universal device for all infusions and transfusions Accurate & Work with all brands of infusion tube Accuracy Error <±5% after calibrated, work with all brands of IV tube: 10d/ml, 15d/ml, 20d/ml, 60d/ml (diameter 3.4mm-4.5mm) Safety and Reliable 2 CPU systems for self-detection; Multiple sensors can detect and monitor the infusion status Multi-functions 12 infusion mode including Programmable infusion mode; Drug Library and history records data can be transferred; WIFI with communication Interface for information system; Warmer for heating.
Specifications of Infusion pump:
Model | Single-channel infusion pump WIT-601A |
---|---|
Communication (Optional) | WIFI, with communication protocol interface for information system |
Warmer (Optional) | Warmer on the side of pump to keep the medical liquid warm |
Drug Library | Library size configurable: More than 1000 drugs & 54 drug dose units |
History Records | Up to 20,000 infusion records |
Data Transfer | RS485 port/compatible with RS232, Wired interface connectable with PC to upload & download data |
Display | High brightness color LCD 3.2-inch screen, Adjustable brightness |
Infusion Mode | Rate/VTBI, Time/VTBI, Rate/Time, Volume, Drop, Micro, Simple Rate, Programmable, DOSE Weight, Drag lib, Auto Bolus, Manual Bolus |
Programmable | 8 programmable sequences of "Time & Flow rate & VTBI" |
IV SET | 10d/mL, 15d/mL, 20d/mL, 60d/mL (diameter = 3.4mm - 4.5mm). Open system for all brands of IV tube |
Accuracy Error | More than 50 bands if V tube feature data can be stored inside the pump |
Calibration | Volume Mode: < ±5%, Drop Mode: < ±2% |
Flow Rate | Automatic or manual calibration |
Flow Rate Increment | Volume: 0.1nm/h~1200mh/h, Drop: 1d/min~400d/min |
VTBI | 0.01m/h |
Total Volume | 0.1~9999.9 ml |
KVO | 0.1~9999.9 ml |
Purgs | Default: 1m/h; 8.1m/h~20mh/h can be set |
Bolus | Keep pushing down "Bolus" button to run the default Bolus parameters. Or click the "Bolus" button to enter the Bolus parameter editable interface |
Upstream Pressure | High / Middle / Low, or OFF |
Downstream Pressure | 20 pressure Levels: 200mmHg; 1200mmHg (mmHg & kPa) |
Bubble | Detected by ultrasonic sensor with adjustable 5 levels, 50μL ~ 90μL |
Drop Sensor | Infrared sensor to detect the drops, monitoring the infusion status |
Alarms | Audio and Visual alarm for: Bubble, Door open, Finish, Pause timeout, Doom Occlusion, Up Occlusion, Lower Battery of damage, Motor error, Memory X Set Prog, Pressure test failure, Motor failure, Abnormal drop rate, Heater failure and etc. 30 kinds safety-monitoring alarm |
Self-detection | 2 CPU systems; Self-detection at startup and running time |
Non-interrupt | Parameters can be modified when pump running |
Keypad Lock | Automatically or Naturally lock the keyboard |
AC Power | AC100V ~ 240V, 50Hz/60Hz, 25Wx. Vehicle-mounted power supply adapter (Optional) |
Battery | Ni-MH battery, DCS 0K, 2000mAh (6 hours at 25m/h rate) |
Electrical Safety Class | Class 1, Type CF, IPX4 |
Install | Can be used either on IV stand, mile or as a table top device |
Weight & Dimension | 2.0kg; 130mm x 120mm x 195mm |
Working Environment | 5°C ~ 40°C; 20% ~ 90% humidity; 70kPa ~ 108kPa atmospheric |
Application | Medical locations such as intensive care unit, pediatric ward, obstetrics and provoking department for computerized autonomous infusion of drugs |